Ceramic-on-Ceramic Bearings in Total Joint Arthroplasty. Part 2
ARTICLE PDF

Keywords

total hip arthroplasty
total knee arthroplasty
ceramics
polyethylene
bearing wear

How to Cite

Zazirnyi, I. (2022). Ceramic-on-Ceramic Bearings in Total Joint Arthroplasty. Part 2. TERRA ORTHOPAEDICA, (3(114), 49-54. https://doi.org/10.37647/0132-2486-2022-114-3-49-54

Abstract

Summary. Total hip arthroplasty (THA) currently provides durable long-term outcomes, but osteolysis secondary to polyethylene wear debris remains a fundamental cause of aseptic loosening and revision. Conventional polyethylene failed to provide a suitable bearing for young active patients requiring joint replacement because of the significant demands they place on such bearings. Strategies to reduce friction and wear debris lead to the development of ceramic bearings in THA. The next decade is unlikely to see a paradigm shift in the materials used for THA. Instead, the challenges will be dedicated to improve surgical technique in terms of component orientation to improve reproducibility and achieve superior patient outcomes. The optimum bearing surface is one with very low wear rates, a low coefficient of friction, scratch resistance, and is biologically inert. It is also one that can safely accommodate larger femoral head sizes to minimize dislocation rates without damaging the taper junction. Such a material already exists with modern ceramic bearings.

https://doi.org/10.37647/0132-2486-2022-114-3-49-54
ARTICLE PDF

References

Jeffers JRT, Walter WL. Ceramic-on-ceramic bearings in hip arthroplasty. State of the art and the future. J Bone Joint Surg Br. 2012;94-B:735–45. doi:10.1302/0301-620X.94B6.

Sukree Khumrak, Thanasak Yakampor Ceramic on Ceramic Bearings. The Bangkok Medical Journal Vol. 4; September 2012. P.93-103.

Bierbaum BE, Nairus J, Kuesis D, Morrison JC, Ward D. Ceramic-on-Ceramic Bearings in Total Hip Arthroplasty. (Dec. 2002). Clinical orthopaedics and related research. Number 405, pp. 158–163. DOI: 10.1097/01.blo.0000038043.63743.9f

Gallo J, Goodman SB, Lostak J, Janout M. Advantages and disadvantages of ceramic on ceramic total hip arthroplasty: A review. Biomed Pap Med FacUnivPalacky Olomouc Czech Repub. 2012 Sep; 156(3):204–212. DOI: 10.5507/bp.2012.063

Aoude AA, Antoniou J, Epure LM, Huk OL, Zukor DJ, Tanzer M. Midterm Outcomes of the Recently FDA Approved Ceramic on Ceramic Bearing in Total Hip Arthroplasty Patients Under 65 Years of Age. J Arthroplasty. 2015 Aug. 30 (8):1388-92. https://doi.org/10.1016/j.arth.2015.03.028.

Allain J, Roudot-Thoraval F, Delecrin J, Anract P, Migaud H, Goutallier D. Revision total hip arthroplasty performed after fracture of a ceramic femoral head. A multicenter survivorship study. J Bone Joint Surg Am. 2003 May. 85 (5):825-30. DOI: 10.2106/00004623-200305000-00009.

Koch CN, Figgie M Jr, Figgie MP, Elpers ME, Wright TM, Padgett DE. Ceramic Bearings with Titanium Adapter Sleeves Implanted During Revision Hip Arthroplasty Show Minimal Fretting or Corrosion: a Retrieval Analysis. HSS J. 2017 Oct. 13 (3):241-247. DOI: 10.1007/s11420-017-9566-4.

Yoo JI, Ha YC, Kim DH, Lee YK, Koo KH. Total Hip Arthroplasty Using Hybrid Ceramic Bearing: A Minimum 10-Year Followup Study. Indian J Orthop. 2019 Sep-Oct. 53 (5):637-640. DOI: 10.4103/ortho.ijortho_416_18.

Hernigou P, Roubineau F, Bouthors C, Flouzat-Lachaniette CH. What every surgeon should know about Ceramic-on-Ceramic bearings in young patients. EFORT Open Rev. 2016 Apr. 1 (4):107-111. DOI: 10.1302/2058-5241.1.000027.

Creative Commons License

This work is licensed under a Creative Commons Attribution 4.0 International License.